Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Chinese Journal of Medical Instrumentation ; (6): 246-249, 2021.
Article in Chinese | WPRIM | ID: wpr-880460

ABSTRACT

In neurosurgery, skull repair caused by surgical approach is one of the important research contents. In this paper, a rapid reconstruction method of the skull defect with optical navigation system is proposed. This method can automatically reconstruct the structure of skull defect with the intraoperative defect edge points and preoperative medical image data. The head model experiment was used to evaluate the effect of the method, the average error of the reconstruction of the defect in the right orbit was 0.424 mm, while the average error of the reconstruction of the defect in the posterior skull base was 0.377 mm. The experimental results show that the structure of the defect is consistent with the actual defect, and the reconstruction accuracy satisfies the clinical requirements in neurosurgery.


Subject(s)
Craniotomy , Surgery, Computer-Assisted
2.
Chinese Journal of Medical Instrumentation ; (6): 27-30, 2018.
Article in Chinese | WPRIM | ID: wpr-774477

ABSTRACT

This paper designed an automatic robotic puncture system for accurate liver cancer ablation based on optical surgical navigation. The near-infrared optical surgical navigation system we constructed for liver ablation was applied to carry out surgical planning and simulation, the near-infrared cameras dynamically tracked the current position of puncture needle relative to the location of the patient's anatomy, then guided the surgery robot to position precisely in three-dimensional space and performed the surgery.


Subject(s)
Humans , Liver Neoplasms , General Surgery , Needles , Punctures , Robotic Surgical Procedures , Surgery, Computer-Assisted
3.
Chinese Medical Equipment Journal ; (6)2004.
Article in Chinese | WPRIM | ID: wpr-583913

ABSTRACT

The ambulatory EEG recorder designed in this paper can continuously record 24-hour EEG signals on 18 channels. C8051F020, a kind of mixed-signal ISP FLASH MCU, controls all the functions such as sampling, storage and many others. The 12-bit ADC in C8051F020 samples the EEG signal amplified by the preamplifier. At the same time, the EEG signal of every channel can be selected through the keyboard to be displayed on LCD so that the working status can be detected. After the system is ready, the signals sampled during 24 hours are stored into the CompactFlash card as FAT16 files.

SELECTION OF CITATIONS
SEARCH DETAIL